Automated ISO / OVF tool methods exist but are not the recommended path
Why
Through the NSX UI (NSX Manager) is the recommended way because it validates prerequisites, deploys and registers the Edge with the fabric, and configures transport-node membership in one workflow, per VMware NSX installation documentation.
Why the others are wrong
B (automated/interactive ISO): supported for special / automated cases, not the recommended default.
C (vSphere Web Client): vSphere can host the VM but does not perform NSX fabric registration and configuration.
D (OVF command line tool): can deploy the OVF but bypasses the recommended NSX-managed workflow.
exam tip
If the question asks for VMware recommended Edge deployment, choose NSX UI / NSX Manager over ISO or OVF tool.
2What is VMware’s recommendation for the minimum MTU requirements when planning an NSX deployment?
MTU should be set to 1700 or greater across the data center network including inter-data center connections.
MTU should be set to 1500 or less only on inter-data center connections.
Configure Path MTU Discovery and rely on fragmentation.
MTU should be set to 1550 or less across the data center network including inter-data center connections.
Answer: A
The short version
Answer A — set MTU to 1700 or greater across the data center network including inter-data center connections.
Key concepts
Geneve overlay encapsulation overhead over physical MTU
NSX minimum MTU planning: 1600 absolute floor, 1700 recommended
Inter-data-center / federation traffic also needs the larger MTU
Why
VMware recommends at least 1700 bytes end-to-end so Geneve-encapsulated frames do not fragment and there is headroom for future features. 1500 is too small for overlay overhead and relying on fragmentation hurts performance.
Why the others are wrong
B (1500 only on inter-DC): 1500 causes fragmentation / drops for Geneve traffic.
C (Path MTU Discovery and rely on fragmentation): fragmentation is what the larger MTU avoids; not a VMware recommendation.
D (1550 or less): below the supported overlay minimum, will break or degrade overlay traffic.
exam tip
Remember 1700 as the recommended NSX MTU; 1600 is the floor often cited for TEP checks, 1700 is the plan-for value.
3In which VPN type are the Virtual Tunnel interfaces (VTI) used?
SSL-based VPN
Route & SSL based VPNs
Policy & Route based VPNs
Route-based VPN
Answer: D
The short version
D — Route-based VPN uses VTIs. Virtual Tunnel Interfaces are a route-based VPN construct for routing decisions.
Key concepts in this question
Route-based VPN: IPsec VPN that uses virtual tunnel interfaces and routing table lookups.
Policy-based VPN: VPN that uses security policies / traffic selectors without VTI routing.
SSL VPN: Remote-access VPN using SSL/TLS, not IPsec VTIs.
Why D is correct
Route-based VPNs in NSX create a VTI to represent the tunnel as a routable interface. This allows static or dynamic routing to direct traffic into the tunnel. SSL and policy-based designs do not use VTIs in this way.
Why the others are wrong
A. SSL-based VPN is for remote access over TLS and does not use IPsec VTIs.
B. There is no combined Route and SSL VPN type using VTIs; it mixes two unrelated concepts.
C. Policy and Route based VPNs as a combined type is incorrect; only the route-based side uses VTIs, policy-based does not.
2V0-4124 exam tip
VTI = Route-based. Policy = selectors, no VTI.
4In an NSX environment, an administrator is observing low throughput and congestion between the Tier-0 Gateway and the upstream physical routers.
Which two actions could address low throughput and congestion? (Choose two.)
Configure ECMP on the Tier-0 gateway.
Configure a Tier-1 gateway and connect it directly to the physical routers.
Deploy Large size Edge node/s.
Configure NAT on the Tier-0 gateway.
Add an additional vNIC to the NSX Edge node.
Answer: A, C
The short version
AC — Scale throughput with ECMP and larger Edges. More paths plus more capacity relieve Tier-0 to upstream congestion.
Key concepts in this question
ECMP: Equal-Cost Multi-Path spreads traffic across multiple Tier-0 uplinks and Edge nodes.
Edge sizing: Large Edge nodes provide higher throughput, more CPU and memory for data-plane processing.
Tier-0 Gateway: North-south gateway connecting NSX to physical routers.
Why AC is correct
ECMP enables active-active use of multiple Tier-0 uplinks and Edge nodes instead of congesting a single path. Larger Edge nodes increase forwarding, firewall, and routing capacity for north-south traffic. Together they directly address throughput and congestion.
Why the others are wrong
B. Tier-1 gateways do not connect directly to physical routers; only Tier-0 provides north-south uplink.
D. NAT changes addresses and does not add bandwidth or resolve congestion.
E. Adding a vNIC to an Edge is not a supported throughput fix and does not create ECMP paths or add data-plane capacity.
5A company security policy requires all users to log into applications using a centralized authentication system.
Which two authentication, authorization, and accounting (AAA) systems are available when integrating NSX with VMware Identity Manager? (Choose two.)
RSA SecureID
SecureDAP
RADII 2.0
LDAP and OpenLDAP based on Active Directory (AD)
Keygen Enterprise
Answer: A, D
The short version
AD — vIDM integrates RSA SecureID and LDAP/AD. Those are the supported AAA sources for centralized login.
Key concepts in this question
VMware Identity Manager: Centralized identity provider for SSO into NSX and applications.
LDAP / Active Directory: Directory service for users, groups, and authentication.
Why AD is correct
NSX with VMware Identity Manager supports enterprise directory integration via LDAP and Active Directory including OpenLDAP based on AD. It also supports RSA SecureID for strong authentication. Both satisfy the centralized login policy requirement. The other listed products are not NSX AAA integrations.
Why the others are wrong
B. SecureDAP is not a supported AAA integration for NSX with Identity Manager.
C. RADII 2.0 does not exist as a product; generic RADIUS is not the listed NSX-vIDM AAA pairing here.
E. Keygen Enterprise is not an identity or AAA system for NSX integration.
2V0-4124 exam tip
vIDM AAA: remember RSA SecureID + LDAP/AD.
6An NSX administrator would like to export syslog events that capture messages related to NSX host preparation events.
Which message ID (msgid) should be used in the syslog export configuration command as a filter?
FABRIC
SYSTEM
GROUPING
MONITORING
Answer: A
The short version
A — Use FABRIC msgid for host preparation. FABRIC captures fabric and host-prep events.
Key concepts in this question
Syslog msgid filter: Message ID used to select which NSX subsystem logs to export.
FABRIC: Subsystem covering transport nodes, host preparation, and fabric health.
Host preparation: Installing NSX components and configuring TEPs on hosts.
Why A is correct
NSX syslog export allows filtering by msgid so only relevant events are forwarded. FABRIC is the designated msgid for fabric-related events including NSX host preparation. Using it isolates host-prep messages from system, grouping, or monitoring noise.
Why the others are wrong
B. SYSTEM covers general system events, not specifically host preparation.
C. GROUPING relates to grouping constructs, not host install and prep events.
D. MONITORING relates to monitoring and alerting, not fabric host preparation.
2V0-4124 exam tip
Host prep logs = FABRIC msgid.
7An NSX administrator wants to create a Tier-0 Gateway to support equal cost multi-path (ECMP) routing.
Which failover detection protocol must be used to meet this requirement?
Host Standby Router Protocol (HSRP)
Beacon Probing (BP)
Virtual Router Redundancy Protocol (VRRP)
Bidirectional Forwarding Detection (BFD)
Answer: D
The short version
D — ECMP Tier-0 requires BFD. BFD provides fast failover detection for ECMP paths.
Key concepts in this question
ECMP: Multiple equal-cost paths from Tier-0 to upstream for scale and resilience.
BFD: Bidirectional Forwarding Detection for sub-second path failure detection.
ECMP relies on rapid detection of failed uplinks so traffic can be rebalanced across remaining paths. BFD is the required failover detection protocol for ECMP Tier-0 in NSX. It converges far faster than routing-protocol timers alone. The other protocols are not used for this NSX ECMP function.
Why the others are wrong
A. HSRP is a Cisco first-hop redundancy protocol, not used for NSX Tier-0 ECMP detection.
B. Beacon Probing is NIC-teaming failover detection, not Tier-0 ECMP path detection.
C. VRRP provides gateway redundancy, not the required ECMP failover detection on Tier-0.
2V0-4124 exam tip
ECMP Tier-0 = BFD, always.
8An administrator has connected two virtual machines on the same overlay segment. Ping between both virtual machines is successful.
What type of network boundary does this represent?
Layer 2 bridge
Layer 2 broadcast domain
Layer 2 VPN
Layer 3 route
Answer: B
The short version
Answer B — two VMs on the same overlay segment that can ping each other are in the same Layer 2 broadcast domain.
Key concepts
NSX overlay segment = logical Layer 2 domain
Broadcast domain: same subnet, direct Ethernet communication, no routing
Bridge vs VPN vs route distinctions
Why
Same segment means same Layer 2 network and same broadcast domain, so ARP/broadcast reaches both VMs and ping succeeds without routing. That is exactly a Layer 2 broadcast domain.
Why the others are wrong
A (Layer 2 bridge): bridging joins two different segments; here there is only one segment.
C (Layer 2 VPN): extends Layer 2 over Layer 3 between sites; not needed for VMs already on the same segment.
D (Layer 3 route): routing connects different subnets/networks; these VMs share one network so no routing boundary is crossed.
exam tip
Same segment + successful ping = Layer 2 broadcast domain; look for route only when subnets differ.
9What are two supported host switch modes? (Choose two.)
Overlay Datapath
Secure Datapath
Standard Datapath
Enhanced Datapath
DPDK Datapath
Answer: C, D
The short version
CD — Standard and Enhanced Datapath are supported. Those are the two NSX host-switch modes.
Key concepts in this question
Standard Datapath: Default N-VDS host switch mode for general workloads.
Enhanced Datapath: High-performance mode using DPDK-style fast path.
NSX documents Standard Datapath and Enhanced Datapath as the supported host-switch modes. Standard suits general virtualization traffic. Enhanced Datapath provides higher packets-per-second for latency-sensitive NFV-type workloads. The other names are not NSX host-switch modes.
Why the others are wrong
A. Overlay Datapath is not a named host-switch mode; overlay is a traffic type.
B. Secure Datapath is not a supported host-switch mode name.
E. DPDK Datapath is a technology used under Enhanced Datapath, not a separately selectable host-switch mode.
2V0-4124 exam tip
Host-switch modes: Standard + Enhanced only.
10Which is an advantage of an L2 VPN in an NSX 4.x environment?
Achieve better performance
Use the same broadcast domain
Enables Multi-Cloud solutions
Enables VM mobility with re-IP
Answer: B
The short version
B — L2 VPN stretches the same broadcast domain. It extends Layer 2 across sites.
Key concepts in this question
L2 VPN: Extends an L2 segment over L3 to another site.
Broadcast domain: Single L2 network where VMs share subnet and broadcast.
VM mobility: Moving workloads without re-IP or gateway change.
Why B is correct
An L2 VPN in NSX allows VMs on different sites to stay in the same broadcast domain and IP subnet. This avoids re-IP during migration and preserves broadcast, ARP, and DHCP behavior. That stretched L2 adjacency is its core advantage. Performance and multi-cloud are not its defining benefit.
Why the others are wrong
A. L2 VPN adds encapsulation overhead and does not claim better performance.
C. Multi-cloud enablement is not the specific L2 VPN advantage; stretching L2 is.
D. L2 VPN enables mobility without re-IP, not with re-IP, so this choice reverses the benefit.